zencontrol offers a range of smart sensors with various features that enable different capabilities within their standalone systems. The following is a summary of the supported features of zencontrol smart sensors:
Functions | zc-pir-iot-np | zc-pir-iot-da-np | zc-pir-iot-da-r-np | zc-pir-iot-da-vf-np | zc-pir-iot-da-2sw-r-np | zc-pir-iot-da-2sw-vf-np |
Sensor Inputs | ||||||
Motion sensor | PIR | PIR | PIR | PIR | PIR | PIR |
Light level | ||||||
Interfaces | ||||||
DALI 101 interface | ||||||
Wireless DALI+ | ||||||
Bluetooth interface (commissioning) | ||||||
DALI PSU | - | - | - | - | - | - |
Inputs | ||||||
Push button input | - | - | - | - | 2* | 2* |
Absolute input | - | - | - | - | 2* | 2* |
Rotary input | - | - | - | - | - | - |
0-10V / 1-10V input | - | - | - | - | - | - |
IR remote | ||||||
Outputs | ||||||
DT7 relay | - | - | 10A | VF10A | 10A | VF10A |
Beacons | ||||||
Eddystone beacon | * | * | * | * | * | * |
Ibeacon | * | * | * | * | * | * |
Lighting beacon | - | - | - | - | - | - |
ECD beacon | - | - | - | - | - | - |
Asset tracking beacon | - | - | - | - | - | - |
LUX control | ||||||
LUX control 101 only | ||||||
LUX control | ||||||
Lux control internal only | - | - | - | - | - | - |
Features | ||||||
Constant light output | ||||||
Addressing mode | ||||||
Timed triggers | - | - | - | - | - | - |
Sequences | ||||||
Bridge (wired & wireless) | ||||||
Corridor mode | * | * | * | * | * | * |
Fallback mode |
*function maybe limited or cannot be used in conjunction with another function depending on the wiring or setup.
Functions | zc-pir-iot-da | zc-pir-iot-da-r | zc-pir-iot-da-vf | zc-pir-iot-da-2sw-r | zc-pir-iot-da-2sw-vf |
Sensor Inputs | |||||
Motion sensor | PIR | PIR | PIR | PIR | PIR |
Light level | |||||
Interfaces | |||||
DALI 101 interface | |||||
Wireless DALI+ | |||||
Bluetooth interface (commissioning) | |||||
DALI PSU | 35mA | 35mA | 35mA | 35mA | 35mA |
Inputs | |||||
Push button input | - | - | - | 2* | 2* |
Absolute input | - | - | - | 2* | 2* |
Rotary input | - | - | - | - | - |
0-10V / 1-10V input | - | - | - | - | - |
IR remote | |||||
Outputs | |||||
DT7 relay | 10A | 10A | VF10A | 10A | VF10A |
Beacons | |||||
Eddystone beacon | * | * | * | * | * |
Ibeacon | * | * | * | * | * |
Lighting beacon | - | - | - | - | - |
ECD beacon | - | - | - | - | - |
Asset tracking beacon | - | - | - | - | - |
LUX control | |||||
LUX control 101 only | |||||
LUX control | |||||
Lux control internal only | - | - | - | - | - |
Features | |||||
Constant light output | |||||
Addressing mode | |||||
Timed triggers | - | - | - | - | - |
Sequences | |||||
Bridge (wired & wireless) | |||||
Corridor mode | * | * | * | * | * |
Fallback mode |
*function maybe limited or cannot be used in conjunction with another function depending on the wiring or setup.
Functions | zc-mw-iot-np | zc-mw-iot-da-np | zc-mw-iot-da-r-np | zc-mw-iot-da-vf-np | zc-mw-iot-da-2sw-r-np | zc-mw-iot-da-2sw-vf-np |
Sensor Inputs | ||||||
Motion sensor | MW | MW | MW | MW | MW | MW |
Light level | ||||||
Interfaces | ||||||
DALI 101 interface | ||||||
Wireless DALI+ | ||||||
Bluetooth interface (commissioning) | ||||||
DALI PSU | - | - | - | - | - | - |
Inputs | ||||||
Push button input | - | - | - | - | 2* | 2* |
Absolute input | - | - | - | - | 2* | 2* |
Rotary input | - | - | - | - | - | - |
0-10V / 1-10V input | - | - | - | - | - | - |
IR remote | ||||||
Outputs | ||||||
DT7 relay | - | - | 10A | VF10A | 10A | VF10A |
Beacons | ||||||
Eddystone beacon | * | * | * | * | * | * |
Ibeacon | * | * | * | * | * | * |
Lighting beacon | - | - | - | - | - | - |
ECD beacon | - | - | - | - | - | - |
Asset tracking beacon | - | - | - | - | - | - |
LUX control | ||||||
LUX control 101 only | ||||||
LUX control | ||||||
Lux control internal only | - | - | - | - | - | - |
Features | ||||||
Constant light output | ||||||
Addressing mode | ||||||
Timed triggers | - | - | - | - | - | - |
Sequences | ||||||
Bridge (wired & wireless) | ||||||
Corridor mode | * | * | * | * | * | * |
Fallback mode |
*function maybe limited or cannot be used in conjunction with another function depending on the wiring or setup.
Functions | zc-mw-iot-da | zc-mw-iot-da-r | zc-mw-iot-da-vf | zc-mw-iot-da-2sw-r | zc-mw-iot-da-2sw-vf |
Sensor Inputs | |||||
Motion sensor | MW | MW | MW | MW | MW |
Light level | |||||
Interfaces | |||||
DALI 101 interface | |||||
Wireless DALI+ | |||||
Bluetooth interface (commissioning) | |||||
DALI PSU | 35mA | 35mA | 35mA | 35mA | 35mA |
Inputs | |||||
Push button input | - | - | - | - | 2* |
Absolute input | - | - | - | - | 2* |
Rotary input | - | - | - | - | - |
0-10V / 1-10V input | - | - | - | - | - |
IR remote | |||||
Outputs | |||||
DT7 relay | - | - | 10A | VF10A | 10A |
Beacons | |||||
Eddystone beacon | * | * | * | * | * |
Ibeacon | * | * | * | * | * |
Lighting beacon | - | - | - | - | - |
ECD beacon | - | - | - | - | - |
Asset tracking beacon | - | - | - | - | - |
LUX control | |||||
LUX control 101 only | |||||
LUX control | |||||
Lux control internal only | - | - | - | - | - |
Features | |||||
Constant light output | |||||
Addressing mode | |||||
Timed triggers | - | - | - | - | - |
Sequences | |||||
Bridge (wired & wireless) | |||||
Corridor mode | * | * | * | * | * |
Fallback mode |
*function maybe limited or cannot be used in conjunction with another function depending on the wiring or setup.
Functions | zc-pms-da-2sw-r | zc-pms-da-2sw-r | zc-mms-da-2sw-r-np | zc-mms-da-2sw-r |
Sensor Inputs | ||||
Motion sensor | PIR | PIR | MW | MW |
Light level | ||||
Multisensor eVOC, eCO2 Hymidity, Sound, Air Quality, Pressure | ||||
Temperature | ||||
Interfaces | ||||
DALI 101 interface | ||||
Wireless DALI+ | ||||
Bluetooth interface (commissioning) | ||||
DALI PSU | - | 35mA | - | 35mA |
Inputs | ||||
Push button input | 2* | 2* | 2* | 2* |
Absolute input | 2* | 2* | 2* | 2* |
Rotary input | - | - | - | - |
0-10V / 1-10V input | - | - | - | - |
IR remote | ||||
Outputs | ||||
DT7 relay | 10A | 10A | 10A | 10A |
Beacons | ||||
Eddystone beacon | * | * | * | * |
Ibeacon | * | * | * | * |
Lighting beacon | - | - | - | - |
ECD beacon | - | - | - | - |
Asset tracking beacon | - | - | - | - |
LUX control | ||||
LUX control 101 only | ||||
LUX control | ||||
Lux control internal only | - | - | - | - |
Features | ||||
Constant light output | ||||
Addressing mode | ||||
Timed triggers | - | - | - | - |
Sequences | ||||
Bridge (wired & wireless) | ||||
Corridor mode | * | * | * | |
Fallback mode |
*function maybe limited or cannot be used in conjunction with another function depending on the wiring or setup.
Functions | zc-th-iot-da |
Sensor Inputs | |
Motion sensor | - |
Light level | |
Presence Sensor | Thermal |
People counting- in / out / total | |
Interfaces |